PTFE-Sealing Thread
PTFE-Sealing Thread
DIN-DVGW (German Association for Gas and Water) for gas and water installations according to EN751-3 FRp
and GRp and DIN 30660 (NV-5143BP0261), tested & approved up to 100
bar pressure in accordance with EN751-3 for gases of the 1st, 2nd and
3rd family and for hot water
DIN DVGW tested & approved for pipe adjustments up to 45°, for hot &
cold & drinking water in accordance with KTW (Synthetic Material in Contact with Drinking Water) recommendations of
the German Health Ministry
WRAS (Water Regulations Advisory Scheme) listed product for United Kingdom Water Regulations Advisory Scheme for
use with hot and cold water (Ref. 0212515)
ASTM F423 Steam & Cold Water Cycle Test - passed
BAM (German Angency for Material Investigation, Bundesanstalt für Materialforschung und -prüfung) tested & approved for use with gaseous oxygen at 30 bar and
100°C (for use with the installation aid, II-2742/2004E)
BAM tested & approved for use with liquid oxygen at 30 bar and 100°C
(use without installation aid, II-2742/2004E)
UL Listed Seal Material 10BN File MH26734 according to Outline 1321
for use in assemblies handling gasoline, petroleum oils, naphta,
propane, butane, benzene, kerosene and natural gas (<300 psig)
KIWA GASTEC Qa (NL): norm. 31, class ”20”
Absolutely chemical resistant to most aggressive chemicals, solvents, fuels
and acids, completely resistant to surface fouling, oxidation, embrittlement
fungal or bacterial growth, enzymatic or microbiological attack
Suitable for solar installations
Installation: Beginning at the end of the thread, wrap in a overlapping
haphazard fashion in the direction of the thread, apply 2 or 3 drops of the
installation aid directly from the separate dispenser and smear over the
PTFE with the finger, concentrate at the end of the pipe and cover only 10 to
15 mm of the thread The manufacturer`s guidelines on the number of wraps
are: 1/2” pipe min. 12 (fine threads) to 18 (coarse threads) wraps
1 1/2” pipe min. 16 (fine threads) to 24 (coarse threads) wraps
For other pipe Diameters adjust the number of wraps which depend on size
and thread, in the case of doubt wrap up more
Temperature range: -200 °C to +240 °C / pressure: 30 bar
up to +100 °C for oxygen, 100 bar for hot water